Glossary

The words of industrial remote access

Each term is defined in general first, then by what it covers in PipeLinker. The definitions point to one another, and each one leads to the page that details it.

From the industrial site to the person working, with no inbound port The equipment - PLC, HMI, controller - is reached by the agent placed on a machine of its own network. The agent opens an outbound connection to the hub you host, and nothing listens on the site. The hub carries the telemetry, the rights, the log and the recordable sessions; the authorised person enters there, and reaches only the targets opened to them. the industrial site your hosting the person working PLC HMI controller agent no port open outbound connection PipeLinker Hub telemetry rights log recordable session granted access authorised user targets opened
The agent calls the hub; nothing listens on the industrial site.

The path, in this order. The equipment - PLC, HMI, controller - is reached by the agent placed on a machine of its own network. The agent opens an outbound flow to the hub you host: nothing listens on the site, and no inbound firewall rule is requested. The hub carries the telemetry, the rights, the log and the recordable sessions. The authorised person enters through the hub, and reaches only the targets opened to them - never the site's network.

Access

OT bastion

A bastion is the mandatory way through to machines that cannot be reached directly: you authenticate there, it decides what you may reach, and it keeps a record of what was done. An OT bastion stands in front of an industrial fleet, where the targets are PLCs, HMIs and control workstations. In PipeLinker, it is the hub, which you host: the OT bastion in detail.

ZTNA (Zero Trust Network Access)

ZTNA grants access to a named service, for one person, on each request, rather than to a network: nothing is reachable until a right opens it. The bastion describes the place, Zero Trust describes the rule. In PipeLinker, every access is a named authorisation, withdrawn in one action.

VPN

A VPN sets up an encrypted link that places a computer inside a remote network. What the person can then reach depends on the segmentation behind it, and per-machine rights or a record of the actions need further controls. Industrial remote access without a VPN compares the families of solutions.

Outbound connection

The device opens the connection to the central server itself, and keeps it: nothing listens on the site, and an outbound internet connection is enough, 4G included. This is what removes the need for an inbound port. In PipeLinker, the agent connects out to the hub: why there is no port to open.

Inbound port

An inbound port is an opening in a site's firewall so that it can be reached from outside. It exposes the site to whoever finds it, and it has to be requested from the IT team that runs the network. An outbound connection does without it.

Declared service

In PipeLinker, a target reachable through an agent, declared by its address, its port and its protocol: a PLC, an HMI, a camera, a remote desktop. The device carries no agent: the agent of a machine on its network opens the final connection. What goes through, protocol by protocol.

Just-in-time access

A right that only exists for the time of a job: requested with a reason, approved, then withdrawn on its own at the end. In PipeLinker, it can open on a future window, carry the work order reference, and require two approvals for a critical target.

Target sensitivity

In PipeLinker, every service, machine or fleet is standard, sensitive or critical, and this rating says what it takes to open it: a security key, a device with a proven posture, recording, an approval.

Recorded session

The course of a terminal or screen session, kept to be replayed with a time slider. It complements the audit log, which says who, on which machine, when and for how long.

Sealed credential

A target's password or key, kept encrypted in the access server and never handed to the person working on it: they get the right to open the session, not the secret, so they can neither keep it nor pass it on.

Identity

mTLS (mutual TLS)

In mutual TLS, the client presents a certificate too, and the server checks it before any useful byte is exchanged. Every PipeLinker agent authenticates this way, with a private key generated on the machine that never leaves it: certificates and keys.

Pinned anchor

A certificate authority of a fleet's own, self-signed, that the server recognises for that fleet only. With no common root, an identity valid in one fleet does not verify in another. It is PipeLinker's default mode; your own PKI remains the other choice, fleet by fleet.

FIDO2 key and passkey

An authentication factor bound to the real site: it does not answer a fake sign-in page, which would otherwise relay the password and the code in real time. In PipeLinker, a role can require one, and other codes then open nothing.

Device posture

The state of a workstation or a phone, checked before an access opens. In PipeLinker, it is proven by the workstation's TPM and by the phone's chip, checked every five minutes, and what stops complying is cut.

The fleet

Hub

PipeLinker's central server, which the customer hosts themselves: one binary and a PostgreSQL database. It carries both the gateway, where the agents' connections arrive, and the bastion, which decides on access. Hosting the hub.

Agent

The software placed on each machine, on Linux, Windows or Android, which opens the outbound connection to the hub. Everything goes through it: telemetry, commands, signed updates and remote access. The agents.

Fleet

In PipeLinker, a partition: a site, a customer or a plant, with its managers and its agents, which does not see the others. Each fleet has its own anchor.

Compliance

Cyber Resilience Act

Regulation (EU) 2024/2847, which sets cybersecurity requirements for products with digital elements sold in Europe. The reporting obligations apply since 11 September 2026, the whole regulation from 11 December 2027. What the fleet has to be able to say.

SBOM (software bill of materials)

The list of a piece of software's components, in a machine-readable format. The one for the product you build is generated in your build chain; PipeLinker, for its part, inventories what is installed on each machine of the fleet.

CycloneDX

A standard SBOM format, read by the tools that match components against vulnerability databases. PipeLinker exports each machine's inventory in this format.

Package URL

A normalised package identifier, which carries the ecosystem, the distribution and the version, not only the name. It is what lets a package be matched with a security advisory, often published per source package.

IEC 62443, zones and conduits

The series of standards on the security of industrial automation and control systems. It groups equipment into zones of the same security level, and governs the exchanges between zones through conduits. PipeLinker's fleet follows this logic of partitioning.

Page last updated on 15 November 2026. Technical page, maintained by the PipeLinker team at LOOTUS SECURITY, publisher of the product. The date comes from the repository, not from a hand edit.